A range by ETS Europe, Belgium.
Hypertectum
Contact
Waterproofing membrane

Hypertectum SS

One-component, silane-based roof coating, UV- and colour-stable.

In short: Hypertectum SS is a one-component, silane-based coating that cures with atmospheric humidity to form a seamless, fully bonded, elastic and watertight membrane.

Use it forRoofs, including roofs with standing water and polyurethane insulation foam, terraces, tanks, planters, and topcoats over polyurethane membranes for colour stability.
Apply withBrush, roller or airless spray, in two to three coats.
Curing timeSkin formation: 2.5 h (23 °C, 50 % RH). Cure: 12-24 h. Between coats: 3-48 h.
CoverageMinimum total (litres): 1.6-2.1 l/m²; Equivalent total (kilograms): 1.98-2.60 kg/m². Depends on surface roughness and project requirements.

Introduction

Hypertectum SS is a one-component, silane-based coating that cures with atmospheric humidity to form a seamless, fully bonded, elastic and watertight membrane. It is highly resistant to standing water and UV- and colour-stable with zero chalking. In white, it reflects solar energy and reduces the temperature inside the building in summer. Apply by brush, roller or airless spray in two to three coats.

Technical properties

Hypertectum SS · See the technical data sheet for test conditions and full specifications.
PropertyValue
Dynamic viscosity (shear rate 100 s⁻¹)2,350 mPa·s
Density1.30 g/cm³
Skin formation time2.5 h at 23 °C, 50 % RH
Curing time12-24 h
Service temperature-40 to +90 °C
Hardness55 Shore A
Tensile strength2.20 N/mm²
Elongation at break350 %
Water-vapour permeability12.7 g/m²·day (23 °C, 0/75 % RH)
WatertightnessWatertight (1 m water column, 24 h)
Adhesion to concrete (with primer)> 2 N/mm²
Accelerated weathering, UV and waterPassed (1,000 MJ/m², 4,000 h)
Thermal ageingPassed (200 days at 80 °C)
Fatigue resistanceNo cracks (-10 °C, 1 mm crack, 1 mm movement, 1,000 cycles)

Colour

White (standard). Grey and red on special order.

Suitable substrates

Concrete, cementitious screeds, bitumen-based coatings and bitumen felts, ceramic tiles, metal, polyurethane foam and polyurethane membranes. For other substrates, contact ETS Europe.

Concrete must be dry and sound, with moisture below 5 %. Remove old coatings. Universal Primer 1K is listed for concrete, Aqua Primer for moist concrete and Universal Primer 2K for bitumen. No primer is needed on non-absorbent surfaces such as ceramic tiles or metal. Follow the limitations on wet substrates and contact ETS Europe for primer selection advice.

System build-up

  1. 01Substrate
  2. 02Primer from the Hypertectum primer range (where required)
  3. 03Hypertectum SS, first coat with geotextile (optional)
  4. 04Hypertectum SS, second and third coat
Hypertectum SS — full specification

Preparation

Remove loose particles, dust and oil. Remove old coatings. Do not wash the substrate with water before application. Seal joints and cracks with Tectflex-PU.

Application

Apply the recommended primer according to its data sheet. Apply the first coat of SS no earlier than 1 h and no later than 48 h after priming.

For better mechanical and crack-bridging properties, embed non-woven, needle-punched polyester geotextile (110 g/m²) in the fresh first coat. Recommended over joints and cracks, at wall-to-floor corners, around chimneys and solar-panel bases, and on cementitious screeds prone to cracking.

For airless spray, dilute with up to 10 % white spirit. Never dilute with water. Apply in two to three coats, leaving at least 3 h and no more than 48 h between coats. Drying time depends strongly on temperature and humidity.

Limits

Not recommended for directly exposed layers in swimming pools, wet substrates or application in rainy weather.

The membrane can be slippery when wet. Broadcast quartz of a suitable grain size into the fresh coating where slip resistance is needed.

Cleaning

Clean tools and equipment with white spirit while the coating is fresh. Cured material can only be removed mechanically.

Packaging and storage

Pails of 0.7 l, 3.6 l and 18 l. At least 12 months in the original sealed pails, in a dry, cool place. Once opened, use all at once. A cured layer forms on top of a part-used pail; remove it and the remaining liquid can be used.

Classification — ETAG 005

The technical data sheet lists: expected working life W3 (25 years); climatic zone S (severe climate); user load P4 (special); roof slopes S1-S4; minimum surface temperature TL4 (-30 °C); maximum surface temperature TH3 (+80 °C); reaction to fire Class E (EN 13501-1).

Safety

See the Safety Data Sheet.