Hypertectum AR
One-component PU base coat, black.
In short: Hypertectum AR is a one-component polyurethane that cures with atmospheric humidity.
Introduction
Hypertectum AR is a one-component polyurethane that cures with atmospheric humidity. It forms a highly elastic, hydrophobic, seamless membrane with excellent adhesion to almost all substrates and excellent resistance to weathering. AR is the black version, used as the first coat; in exposed applications it must be finished with Hypertectum AF (white or grey) as the second coat.
Technical properties
| Property | Value |
|---|---|
| Elongation at break (23 °C) | > 500 % |
| Service temperature | -40 to +90 °C |
| Max. short-term (shock) temperature | 200 °C |
| Hardness | > 60 Shore A |
| Tensile strength at 23 °C | > 60 kg/cm² (> 6 N/mm²) |
| Adhesion to concrete | > 20 kg/cm² (> 2 N/mm²) |
| Water vapour transmission | 0.8 g/m²·h |
| Viscosity (Brookfield) | 3,000–6,000 cP |
| Density | 1.35–1.45 g/cm³ |
| QUV accelerated weathering | Passed (2,000 h) |
| Thermal resistance (100 days at 80 °C, EOTA TR011) | Passed |
System build-up
- 01Substrate
- 02primer (where required)
- 03Hypertectum AR as the first coat (0.7–0.9 kg/m²)
- 04Hypertectum AF as the second coat (0.8–0.9 kg/m²)
Minimum total consumption: 1.5–1.8 kg/m².
Hypertectum AR — full specificationBefore you start
Remove loose material, dust, vegetation, salts, oil and grease. Grind off and remove loose parts. Where the membrane is applied without reinforcement, repair major cracks with Tectflex-PU before the final coat.
No primer is needed when all of the following apply: concrete strength C20/25, surface moisture < 5%, application temperature 5–35 °C, relative humidity < 85%. In all other cases, select a primer from the Hypertectum primer range.
Suitable substrates: concrete, fibre-cement sheets, terrazzo, roof tiles, sound acrylic and bituminous coatings, wood, oxidised metal. Galvanised steel and aluminium require the appropriate primer.
Application
Mix by hand or with a low-speed mixer for about 10 minutes. Apply by roller, brush or airless spray (200–250 bar). Apply successive coats every 6–24 hours, depending on weather conditions. For details, embed a reinforcement fleece in the first coat.
Limitations
Not recommended on substrates with low cohesion or in swimming pools in direct contact with chemically treated water. In exposed applications, AR must be top-coated with AF.
Cleaning and storage
Wipe tools with dry paper or cloth, then clean with a suitable solvent. Re-using rollers is not recommended. Contains flammable solvents: keep away from naked flames and sparks and provide adequate mechanical ventilation. See the safety data sheet.
Pack sizes: 1, 6, 15 and 25 kg. At least 12 months in the original unopened containers, in a dry place at 5–25 °C. Once opened, use immediately.